The Centrifugal Range
THE CENTRIFUGAL RANGE has been designed for the ventilation of internal areas requiring longer lengths of ducting. All with a 100mm air outlet, back draft shutters as standard and a range of control options for added efficiency, they can also be switched remotely with our optional remote controllers.
- NEW AVC110LV low voltage model
- Suitable for wall or ceiling mounting, except pull cord.
- 'Back draft' shutter as standard
- AVC 060: 25 litres/sec
- AVC 110: 31 litres/sec
- AVC 215: 60 litres/sec
* The recommendation for use in specific room types assumes average dimensions, ie a very large bathroom may require an AVC 215.

Performance
Model |
Airflow M³/hour |
litres/sec |
Max pa | dB(A) @2m |
Power (W) |
AVC 060 |
90 |
25 |
80 | 42 |
25 |
AVC 110 |
110 |
31 |
120 | 45 |
45 |
AVC 110LV |
110 |
31 |
120 | 45 |
25 |
| AVC 215 | 215 | 60 | 180 | 56 | 60 |
Installation and Technical Data
RATING: 220-240V ~AC~50Hz; IP24, AVC110LV: 12V
AC ~50Hz; IP44
;
CONSTRUCTION: double insulated impact resistant ABS thermoplastic;
MOTOR: single phase induction motor with pre-oiled bearings. Thermal overload protection;
MAX OPERATING TEMPERATURE: 40°C.
Accessories
- AVA050 100mm x 10m Flexible Aluminium Duct.
- AVA100 100mm x 1.5m Rigid Aluminium Duct.
- AVA120 100mm PVC Ducting 3m.
- AVA130 100mm x 10m Insulated Ducting.
- AVA150 100mm Fixed External Grille (Grey).
- AVA160 100mm Gravity Shutter (Grey).
- AVA270 100mm Through Wall Vent Kit.
- AVA351 Remote Timer.
- AVA361 Remote Humidistat
- AVA362 Remote PIR.
- AVA440 100mm Condensation Trap.
- SYSTEM 54
- SYSTEM 60
For Low Voltage Only
- LRT12T Large Timer transformer.
- LRT12H Large Humidistat transformer.
Technical Downloads
AVC060 Installation Instructions File Size: 6288k




For further info on IP ratings click here
Specifications
- AVC060SN Standard model.
- AVC060PN Pull cord model.
- AVC060TN With integrated adjust. timer: 1-20 MINS.
- AVC060HTN Adjustable Humidistat model; RH: 40-90%, timer: 1-20 mins.
- AVC060HPN As above, with Pull cord.
- AVC110S Standard model.
- AVC110P Pull cord model.
- AVC110T With integrated adjust. timer: 1-20 mins.
- AVC110HT Adjustable Humidistat model; RH: 40-95%, timer: 1-20 mins.
- AVC110HP As above, with Pull cord.
- AVC110LV Centrifugal low voltage model.
- AVC215S Standard model.
- AVC215P Pull cord model.
- AVC215T With integrated adjust. timer: 1-20 MINS.
- AVC215HT Adjustable Humidistat model; RH: 20-90%, timer: 1-20 mins.
- AVC215HP As above, with Pull cord.